5mm, does this mean I use a 2. You can effortlessly plug it into a standard 13 amp electrical socket without the need for specialised wiring or professional help. I don't think so, the hob is currently gas and the oven electric just plugged in to a double socket at the back. My existing one is wired into a normal 30 amp cooker switch/socket. Stainless steel finish. Hob Type: Induction Hob. I want to get a new hob. 00 mm cable and a 32 amp circuit breaker will be appropriate. 00mm. You should use the existing cooker circuit for the new oven, to reduce the load on the ring (socket) circuit. com. ★★★★★ Read 9 reviews. Bazza, Apr 26, 2022. Coloumb Screwfix Select. The safety. 5 hr flex is fine if its a gas one 1. Double 13A sockets are only designed to handle 20amp. If it is 7000W, this would be 29A at 240V, so 4mm2 flex (which could theoretically handle about 32A) should be OK. READ NEXT: Best gas hobs. There is a switch on wall by oven. £72. com. Repair Service Action. Repair Service Action. Available with or. 4. Screwfix Select. Single oven yes. Hi everyone. The thread also includes links to products and specifications of different hobs. Product code: 401376. It's a heavy base wok so distributes heat evenly unlike a thin carbon steel wok. However, he seems to have second throughts. com. Where two stationary cooking appliances are installed in one room, one. Screwfix customers rate this product 4. Having an existing gas hob and electric oven (under counter) replaced. FREE next day delivery available, free collection in 1 minute. 49 Inc Vat. . 5 +21. 1/5. #3. . 1 2. Screwfix Community Forum. 5mm2. Repair Service Contact. I feel like I should take the hob out and put some sort of tape/barrier round. I'm currently changing my hob for a new one. Available in styles & finishes to suit your kitchen. All on a 40amp breaker or would it be best to de-rate down to. 4KW load, ideally I'd like to be able to have the 20Amp option to get the most out of it. It doesn't trip every time I switch it on. 276. furious_customer, Oct 2. all 3 requie hard wiring. , Mar 15, 2018. C. Repair Service Action. Hi there. Cooke & Lewis CLCER30A Ceramic Hob Black 60mm x 290mm (777FK) compare. Repair Service Contact. Home Forums > Screwfix Community Forum > Electricians' Talk > New electric hob. sinewave, Mar 24, 2007. com. Order Cooke & Lewis GASUIT4 Gas Hob Stainless Steel 83mm x 580mm at Screwfix. Neither the hob or the oven should be more than 2 Mts from the control. Done right it could look quite good. Buy Cooker Hoods at Screwfix. Ah ok so it's the same wiring as an electric hob, but slightly more complex is that right? HannahBanana, Sep 13, 2017. Can't really. Cooke & Lewis CLCER30A Ceramic Hob Black 60mm x 290mm (777FK) Cooke & Lewis CLCER30A Ceramic Hob Black 60mm x 290mm. Screwfix Community Forum. This being sufficient worktop to support the hob. Well the hob is rated at 7. 5 mm flex seemed a bit lightweight for the hob. Hotpoint TQ1460SNE Electric Induction Hob - Black. This is why 3kW immersion heaters are on separate circuits. Sepparate Ovens (in general) can be run off a socket outlet, and indeed come with a 3 pin plug attached. Order Cooke & Lewis GASUIT4 Gas Hob Stainless Steel 83mm x 580mm at Screwfix. Order online at Screwfix. stateit Screwfix Select. Touch-operated ceramic hob ideal for smaller cooking areas. (6mm2 T&E feed to switched spur, 2. 98 Inc Vat. sfrazi New Member. Child Safety Lock Mechanism. An induction hob is an electric hob, just has an increased power rating (normally) Dr Bodgit, Sep 13, 2017. I think I'm going to use silicone. The question is this. Frustrated female New Member. Please do not return to store. £5. I'm currently changing my hob for a new one. Wide range available. Most DOUBLE electric ovens are rated over 3kW and require their own 32A radial circuit and will not have any connection pre-wired. 0800 324 7818. sinewave Screwfix Select. Delivery. 25m Length. I have looked at it and there is no give in the wire to move it out of cooker. 7 KW) Induction or 2 x Ø 190 mm, 2. Child Safety Lock Mechanism. Best electric hob: At a glance. 5kw respectively. The cooker switch is on the opposite wall to the hob so I couldn’t wire it there even if I wanted to. Cooke & Lewis CLIND60 Induction Hob Black 68mm x 590mm. Cooke & Lewis CLCER30A Ceramic Hob Black 60mm x 290mm (777FK) compare. Davie Active Member. . Bazza, Feb 4, 2022. 9 adjustable power levels per zone. wrighty wrongy Member. Single oven yes. #4. As others have said, look for the rating label on the hob, to use a 13A plug successfully it should not exceed 3. For a electric hob, the minimum space above it is 600mm. Easy-Tear. those are the cables supplied. A dedicated 32A cable runs from the CU to the oven. Old hob specs from data sheet below. 2 x Plate Sizes. The oven goes on a 13A plug, so that's straightforward. Can I run the oven off the same supply if I tee into. Hello, got a new induction hob to replace an old electric hob (the old style with raised heat elements that take an hour to heat up then 3 hrs to cool down) it is all plumbed in with a big red switch and theres a junction box behind the cooker for easy change over, just wanted to know is it just a case of connecting the right wires up and. Repair Service Contact. 1. It shows 2 live terminals. Timer. Order Cooke & Lewis CLCER60a Ceramic Hob Black 52mm x 590mm at Screwfix. My electric Zanussi hob has recently started tripping the mains electric. From the photos, it’s pretty clear that the glass cooktop has detached from the frame that holds it into the recess. 5mm cable, supplied from a 45A cooker switch, which is supplied via 6mm cable, protected by a 40A MCB in the CU. Should an ceramic electric hob go through an rcd? the one i have if wired through the rcd trips it out when switched on. Flexible delivery available. It goes straight down into the ground, underneath the kitchen floor tiles, over to the other side of the kitchen where it is hardwired in. Free next day delivery available. P Ramejkis New Member. Discussion in 'Painters' Talk' started by Tpage16, Dec 19, 2022. 0mm H05 flex for hob to outlet plate as it’s current demand is 30. The plug limits the maximum power output to 3 kW. Raised Square Profile. Yes, they would work perfectly well if plugged in on a 13A socket but the circuit would quickly overload when other appliances were plugged in. The problem is the customer. To neatly finish off the paint job I am looking for a heat safe sealer to seal around the end of the hob / slightly underneath it where I can’t quite get the paint. Screwfix customers rate this product 4. The connection units will be fine behind. If you must go the FCU route then just go on the Screwfix site and type FCU in the search box. 2 x Plate Sizes. 5mm cable, supplied from a 45A cooker switch, which is supplied via 6mm cable, protected by a 40A MCB in the CU. 5MM2. I’m not an expert in this field but as it is would seem the back right hob ring will be very close to the gas supply pipe running down the wall. Is it OK for an electric hob to touch wood struts directly underneath? 2. Screwfix Community Forum. Looking at the oven although its 880 height (including legs) the top is basically the controls with beding that 40mm lower. 6a = 24. If you had a gas hob, the minimum distance would be 150mm under the gas regs. Deals and Offers. Discussion in ' Electricians' Talk ' started by Curiouscat, Jan 26, 2009 . Products reviewed by the trade and home improvers. I went round the house turning everything off and finally identified the culprit - my gas hob! I turned it off at the isolator switch above the worktop and then I. Brown, Black, Blue, Grey & Green/Yellow Cores. 2 x Ceramic Plates. Screwfix London Victoria. 27 Strands Per Core. View all: Unika Worktop Fittings. Home Forums > Screwfix Community Forum > Electricians' Talk > Electric Oven and Electric Hob Discussion in ' Electricians' Talk ' started by RedRick , Nov 8, 2004 . 79Inc Vat. Simple to clean. 3/5. You could always think of another way though. Having ploughed through loads of specification on AO. In the main an electric hob needs letting into the work top, where a gas one has a recess in the design to catch spills, what you don't want is for the spill to run off the hob onto the work top making any items on the work top wet, my induction hob is around a 1/16 of an inch lower than work top. Click & Collect. seneca Screwfix Select. LAP 45A 2-Gang DP Cooker Switch & 13A DP Switched Socket Brushed Stainless Steel with Neon with Black Inserts (96499) Huge range of Cooker Switches at Screwfix. Electric hobs are compatible with any material but it’s important the bottom of. 82 would be the total loading, yes 10mm ok with a 40amp breaker. To install the new induction hob this needs to be hardwired. It's explained in the hob manual. No refill required. com it seems the vast majority of the cheaper single ovens only take 13amps, some even come with a 13 amp socket. My electric Zanussi hob has recently started tripping the mains electric. View product Smeg SI4642D_BK 60cm Electric Hob - Black £. robertpstubbs Screwfix Select. stateit, Jan 11, 2014. One of the biggest advantages is the ease of cleaning as you just have a sheet of glass to wipe over, with no burnt on food. Child Safety Lock Mechanism. Hi, i recently had gas hob/ electric oven fitted, after it was done the gas engineer said the plug socket which is above the oven needs moving. 49 Inc Vat. So I think I can just plug the oven into the ring main and use the 32amp feed for the hob. The hob can run on 6mm and even 2. 99 More info. Add to basket. I think I might be able to explain why the hob has two cables. I have a new electric hob , the earth terminal is marked but the other 2 are not so does it matter which goes to the live and. Odourless. I read the instruction manual and it said for 240v connections to put the brown/black wires together on the live circuit, earth for earth and the blue/grey wires on the neutral. I have an existing 6mm cooker cable direct from the consumer unit approx 10M long currently protected by 32a mcb. 5 mm cables. Product information. 04 amps. 00. Unphased - all noted thank you. I have a electric hob (input 5500W) which my electrician has connected to the cooker switch using a 6mm T+E cable. -exterior cable diameter should be at least 8. any help on this would be greatly. 0800 324 7818. Suitable for Indoor use. 8kw. It must only be a small induction hob to come with a plug though. Fires, Stoves & Electric Heating Heaters Oil Filled Radiators Underfloor Heating Electric Radiators Stoves Fireplaces Ventilation Extractor Fans Fans Air Conditioning Ducting. Other users reply with their opinions and advice, including the difference between. 1KW/32amp. 30 day money back guarantee. Stock Number ES1781989. All that said there are practicalities that come into. You would use a dual cooker connection unit ,and connect both to it. It will need a 13A fuse, which will come with it. Total Product Weight. 2KW which is 32 Amps, the oven is on top of that. com. So for a new cooker circuit, will they install a double socket under the worktop to plug in the electric oven and electric hob, then a single fused switch above worktop to control both at the top like this?Chris Sanderson New Member. I have seen one oven and hob at 10. 5KW electric hob. The 6mm cable will only feed the hob there will be another circuit for the oven. Upgrade your kitchen with a hob from premium brands like AEG, Siemens and Bosch. Free next day delivery available. ie. My question is, what is an omnipolar cut. We’re replacing our gas oven with an electric oven but keeping the gas hob. Finally, a relative has a NEFF hob the same age as ours and the glass where the pans sit has a slightly lower sheen, more like eggshell than rest of the high gloss glass. Pay your way. The wiring diagram is as follows Earth Terminal - L1 -L2 -L3 Terminals and finally Neutral Terminal I've obviously put the earth and neutral where they are supposed to go, but I've put the live in L1. Delivery. Wouldn't that mean a 50a RCB and probably 10mm2 cable? Moldy1, May 10, 2017. Advice please,thanksSiemens iQ100 60cm 4 Zone Touch Slider Control Induction Hob. Buy any 10+ Save 10% - View Offer. (a common problem on older oven and hob elements). 6A) Oven - 3. There is nothing wrong with this and it's within the Regs and done all the time. Apple Pay accepted in store. Low price guarantee at BestBuy. Oven is 880mm. Also, there is a burning smell and some fumes coming out from under the hob and between the gap in. One other thing is that the hob as well as other appliances connect to a 80amp mcb as we had the kitchen redone a few years ago. Samsung NZ84F7NC6AB_BK 80cm Electric Hob - Black (2) £ 818. 0800 324 7818. I would prefer to have oven and hob on cooker circuit, then separate 20a circuit for microwave, which could also accommodate extractor hood too. 0800 324 7818. Which is what you require. 25. I too am wanting to do this. I do not have the luxury of being able to run a new cable from the CU, not without a lot of disruption to many rooms. Cooke & Lewis CLCER30A 29cm Ceramic Hob - Black. Saving energy at home. Click & Collect. MGW Screwfix Select. Heat-Resistant. The oven circuit is fused at 32A. You simply use a standard cooker circuit. Promote a healthy airflow. Order Cooke & Lewis CSB60A Built- In Single Electric Oven Stainless Steel 595mm x 595mm at Screwfix. Neither the hob or the oven should be more than 2 Mts from the control. The new hob is over 3kw, and they advise I need a 16Amp or 32Amp fuse - a big red switch. If you have blades which cut on the upstroke, then you should lay the worktop upside down and cut that way. Hi all, Currently in the process of modernising our extremely old kitchen. Our Culina electric ceramic hobs are available in 30cm and 60cm in white and black designs to fit a variety of kitchen interiors. PayPal accepted online. But there's not the prescribed 15mm of space between the oven and worktop - it's covered with a small wood panel that's started to fall down on one side. 1KW/32amp. Unfortunately there are no regs for electric hobs of any type. It has a sleek, frameles READ MORE. Frustrated female New Member. Cooker is reactivated by resetting the system once the cause of the alert has been investigated and controlled. I am planning my kitchen and the hob I have chosen is 7. Includes baking tray, trivet and shelf. Cool White. 0800 324 7818. 3kw induction hob on its own radial circuit protected by a 32amp MCB. The circuit supplying your existing oven will most likely be a standard 32A cooker circuit wired in 6mm2 T&E. Its a good bet that the socket will fail after some use. #11. £289. I do not know of any electric hob that will utilise a 13amp plug . hob is 6kw - 26 amp cooker 2. alex250, Aug 1, 2004 #1. 99 Inc Vat. Instant heat and easy to manipulate to the required temperature. 5kW blasting away in all. Screwfix Community Forum. oven and hob are both electric hob has electric plates. rogerk101 Screwfix Select. 5mm" and that "for this connection a power lead of wire type H05VV-F should be used". Cooke & Lewis CLCER30A Ceramic Hob Black 60mm x 290mm (777FK) compare. According to Neff, for the hole cut out of the worktop, the minimum front and back distances from hob to back wall and front edge to counter are 50mm. €91. Buy Cable at Screwfix. The work top is 600mm. Buy Electric Hobs at Screwfix. Buy a bundle. 10mm would be best as this is a slightly larger than normal cooker. ABS Plastic. If you had a gas hob, the minimum distance would be 150mm under the gas regs. Hisense BI64211PB Built-in Single Multifunction pyrolytic Oven - Black. Currently the oven is left disconnected. Permanent Adhesive. FREE next day delivery available, free collection in 1 minute. most hobs need minimum of 4mm cable and a 32 amp fuse at the consumer unit supplying only the hob. Screwed Faceplate. Child / User Safety Control Lock. If it has a plug, add a 13A socket to the cooker circuit. 00. £10. They are: 1) 220-240V 1N ~ H05V2V2-F 3G 2. We've been using induction hobs since 2009. Most sockets feeding things like dishwashers and washing machines are mounted inside an adjacent cupboad. Wiring a 7. Screwfix customers rate this product 4. I want to run the cable from the kitchen to the cupboard where the consumer unit is myself and then get the electrician to install the ovens and hob at one end and do the work on the consumer unit (we may need a new consumer unit but the electrician sill sort all that out). The current electric hob surface dimension is 77 x 51 cm with the hole being 75. 2 x Plate Sizes. Now we take off the first 10 amps and then use 30% of the remainder so, 33. I've cabled up to a CCU in 6 mm cable for an electric hob. Neither have any cables attached, but both state 4mm cable on the connection points. Control Type: Touch. com. Hobs are at the heart of any kitchen, and are great for creating quick, delicious meals for friends and family. The built-in Neff B57CR22N0B Slide & Hide Electric Oven is spacious and packed with plenty of different functions that allow you to cook the way you want. If their is an outlet plate on the wall behind the original cooker position, you can connect to this with the 2 extra cables. British General 900 Series 45A 1-Gang DP Cooker Switch White (45659) (23) £7. I have Electric Oven/Gas Hob that I am replacing due to age. So for a new cooker circuit, will they install a double socket under the worktop to plug in the electric oven and electric hob, then a single fused switch above worktop to control both at the top like this? If the induction hob will run on 16A single phase, the results will be disappointing. com. 2A) Applying diversity gives 100% of the first 10A plus 30% of the remaining 35. Home Forums > Screwfix Community Forum > Electricians' Talk > AG Electric Hob ? Discussion in 'Electricians' Talk' started by Sharon151, Jun 21, 2014. Turn off the 32amp MCB to check. From the photos, it’s pretty clear that the glass cooktop has detached from the frame that holds it into the recess. The Sigma3 countertop depth is the standard 600 mm but the splashback thickness (approx 15 mm) clearly reduces the useable depth to less than the minimum 600 mm required by Neff. Its always better to have these sorts of load on a dedicated circuit. Induction hob heats the surface of the pan, not the surrounding area, ensuring cooking is quicker and more efficient. Heat-Resistant up to 600°C. Some of the hobs are pretty pants for sitting flat on the worktop. If no flex is fitted ,likely to require hard wiring back to the CU, with local isolation, usually in adjacent cupboard or above worktop. Discussion in 'Electricians' Talk' started by alex250, Aug 1, 2004. Ideally you need an electrician who is capable of undertaking kitchen fitting and knows a gas fitter. Delivered by our approved supplier, Find out more. Child Safety Lock Mechanism. Choose options. Hob is 6KW. The installation instructions for the induction hob state that it requires direct connection to the mains and requires a 32A. I have bought a new kitchen. Under worktop oven. Total Product Weight. It's rated at 32 amp, recently got my entire fuse box re-done a few months back due to problems with it and I've no idea if this is supported. (of course, make sure your sink and hob cut outs are properly templated out! -seal the cut edges of the worktop before fitting the sink/hob. In the main size of cable is dictated by the size of the protection device, so we have 32, 40, 45 amp, but in the main we use 32 amp, as ovens really do not want a higher valve device when only designed for 16 amp, the cable manufactures do charts looking at the chart it seems 4 mm would do, but I would likely. 7 KW) Induction or 2 x Ø 190 mm, 2. Snezza31New oven & hob query. Currently in my kitchen we have a range cooker with an electric oven and a gas hob. £13. As you probably know, induction hobs work by turning electricity into magnetic currents that in turn agitate the food molecules in the pan, not by actually heating the pan. 2A (=10. Cuts off the electricity supply if the hob has been left on accidentally. The current setup is as follows: CCU>1xB32 MCB>connected to 2x red cooker switches: - Switch 1: connected to hob above.